Latency
280–3,000 msTypical cloud round trip, against a clinical need for feedback in under 100 ms. On sidelines and in rural clinics, connectivity isn't guaranteed at all.
HARP Research · the long game
A headset gives a precise check when someone runs a test. We're researching always-on, ultra-low-power sensing that keeps each athlete's personal baseline on the device itself, with no cloud and no headset.
The gap
Latency
280–3,000 msTypical cloud round trip, against a clinical need for feedback in under 100 ms. On sidelines and in rural clinics, connectivity isn't guaranteed at all.
Power
14–22 WhWhat a headset draws. A device worn all day in the field needs to run a full assessment on under 1 Wh, a gap of about 20×.
Signal
10–20 msHow long a microsaccade lasts. The clinically useful signal is sparse and fast, while standard cameras spend almost all their compute on frames where nothing changes.
Fragmentation
4+Separate systems for balance, gaze, reaction and vestibular data today. Nothing fuses them into one real-time picture of a person.
Figures from HARP's research analysis. References are in the technical brief.
How we tested it
Before designing any hardware, we asked whether an always-on, on-device wearable could do the job at all, and where it would break.
Findings
Finding 1 · what doesn't work
99.96%Concussions are rare compared with the number of hits an athlete takes. At real-world rates, an alarm that only listens for impacts would need to be right about 99.96% of the time it stays quiet, or it buries staff in false alarms. That isn't a realistic target.
So: objective, structured assessment of how the brain is functioning, the approach HARP already takes, is the right foundation. Impact alarms alone are not.
Finding 2 · where the hard problem is
MemoryPersonal baselines are what make a result meaningful. Holding them accurately on a tiny wearable for a whole season, without sending data to the cloud, is the real engineering problem.
We've developed an approach to it. The details stay private until our filing decision and are shared only under NDA.
Simulation results only. Nothing here has been tested in hardware or on people yet.
What it enables
The approach doesn't care which signal it tracks, so the same idea works for heart rate, gait, brain activity or any measure that has a personal normal.
A season-long baseline for every athlete, worn in training and matches, feeding HARP's assessments.
Recovery tracked between clinic visits against the patient's own normal, not a population average.
Machines that learn their operator's normal and adapt, entirely on the device.
Health baselines that work where there's no connection and every milliwatt counts.
Why it compounds
Status
We're working through a filing decision with NUS, and we'll publish the full study once it's made.
16 experiments with negative controls.
The combination appears to be new.
A record of invention, ready for review.
Working through the university's innovation office.
A first sensor prototype, and the study published once protected.
Investors and research partners
The full study, the approach and our hardware roadmap, shared under a mutual NDA. We reply within two working days.
Back to the HARP platform